Linksys SFE2010 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Accessoires pour ordinateurs Linksys SFE2010. Linksys SFE2010 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - ADMIN GUIDE

ADMIN GUIDEBUSINESS SERIES48-port 10/100 Ethernet SwitchModel: SFE2010/SFE2010P

Page 2 - Table of Contents

SFE2010/SFE2010P Administration Guide 7Placement OptionsConnecting Devices CAUTION: Keep enough ventilation space for the Ethernet switch so it does n

Page 3

SFE2010/SFE2010P Administration Guide 8Connecting the CablesConnecting Devices Wall-Mount Placement1. On one of the side corners, remove the four fron

Page 4 - Introduction

SFE2010/SFE2010P Administration Guide 9Connecting the CablesConnecting Devices CAUTION: Observe the orientation of the mini-GBIC module before inserti

Page 5 - SFE2010/P Front Panel

SFE2010/SFE2010P Administration Guide 10Connecting to the Switch with the Web-Based Utility Web Utility Configuration 4Web Utility Configuration This

Page 6 - Feature Description

SFE2010/SFE2010P Administration Guide 11Viewing On-line Help Web Utility Configuration Viewing On-line Help The Web Utility has on-line Help including

Page 7 - SFE2010/P Back Panel

SFE2010/SFE2010P Administration Guide 12Connecting to Your Switch with HyperTerminalUsing the Console5Using the ConsoleThis chapter describes the use

Page 8

SFE2010/SFE2010P Administration Guide 13Connecting to Your Switch with HyperTerminalUsing the Console1. Click the Start button. Choose Programs > A

Page 9 - Placement Options

SFE2010/SFE2010P Administration Guide 14Connecting to Your Switch with HyperTerminalUsing the Console4. Set the serial port settings as follows: • Bit

Page 10 - Connecting Devices

SFE2010/SFE2010P Administration Guide 15Connecting to the Switch with TelnetUsing the ConsoleConnecting to the Switch with TelnetYou can connect to th

Page 11 - Connecting the Cables

SFE2010/SFE2010P Administration Guide 16Using the Switch Main MenuUsing the ConsoleUsing the Switch Main MenuThe Switch Main Menu provides access to s

Page 12

SFE2010/SFE2010P Administration Guide iTable of Contents1 Introduction . . . . . . . . . . . . . . . . . . .

Page 13 - Web Utility Configuration

SFE2010/SFE2010P Administration Guide 17System ConfigurationUsing the Console3. Username & Password Settings (see page 24)4. Security Settings (se

Page 14 - Viewing On-line Help

SFE2010/SFE2010P Administration Guide 18System ConfigurationUsing the ConsoleVersionsUse the Versions screen to display the boot, software, and hardwa

Page 15 - Using the Console

SFE2010/SFE2010P Administration Guide 19System ConfigurationUsing the ConsoleTo change the system contact, system name, and location:1. Select Edit, a

Page 16

SFE2010/SFE2010P Administration Guide 20System ConfigurationUsing the ConsoleSerial Port ConfigurationUse the Serial Port Configuration screen to view

Page 17

SFE2010/SFE2010P Administration Guide 21System ConfigurationUsing the ConsoleTo open this screen:1. From the Switch Main Menu, select 1. System Config

Page 18 - Logging On to the Console

SFE2010/SFE2010P Administration Guide 22System ConfigurationUsing the ConsoleSSH Server ConfigurationUse the SSH Server Configuration screen to view o

Page 19 - System Configuration

SFE2010/SFE2010P Administration Guide 23System ConfigurationUsing the ConsoleTo open this screen:1. From the Switch Main Menu, select 1. System Config

Page 20

SFE2010/SFE2010P Administration Guide 24System ConfigurationUsing the ConsoleTo generate the crypto key:1. Verify that the information is correct.2. S

Page 21

SFE2010/SFE2010P Administration Guide 25System ConfigurationUsing the ConsoleNOTE: The default user is “admin” with no password.To open this screen:1.

Page 22

SFE2010/SFE2010P Administration Guide 26System ConfigurationUsing the ConsoleSSL Generate CertificateUse the SSL Certificate Generation screen to view

Page 23

SFE2010/SFE2010P Administration Guide iiTable of ContentsA Contacts . . . . . . . . . . . . . . . . . . . .

Page 24

SFE2010/SFE2010P Administration Guide 27System ConfigurationUsing the ConsoleShow CertificateUse the Show Certificate screen to display the internal c

Page 25

SFE2010/SFE2010P Administration Guide 28System ConfigurationUsing the ConsoleVLAN ManagementThe VLAN Management menu provides access to a screen where

Page 26

SFE2010/SFE2010P Administration Guide 29System ConfigurationUsing the ConsoleTo edit the VLAN ID:1. Select Edit.2. Type the VLAN ID.3. Press the Esc k

Page 27

SFE2010/SFE2010P Administration Guide 30System ConfigurationUsing the ConsoleIPv4 Address ConfigurationThe IPv4 Configuration menu provides access to

Page 28

SFE2010/SFE2010P Administration Guide 31System ConfigurationUsing the Console4. From the IPv4 Address Configuration menu, select 1. IPv4 Address Setti

Page 29

SFE2010/SFE2010P Administration Guide 32System ConfigurationUsing the Console1. IPv6 Interface Enable (see page 32)2. IPv6 Address Settings (see page

Page 30

SFE2010/SFE2010P Administration Guide 33System ConfigurationUsing the Console3. Select Save to save your settings4. When the Operation complete messag

Page 31

SFE2010/SFE2010P Administration Guide 34System ConfigurationUsing the ConsoleIPv6 Address TableThe IPv6 Address Table lists the IPv6 addresses that ar

Page 32

SFE2010/SFE2010P Administration Guide 35System ConfigurationUsing the ConsoleTo edit the ISATAP tunnel settings1. Select Edit., and then make the chan

Page 33

SFE2010/SFE2010P Administration Guide 36System ConfigurationUsing the ConsoleIPv6 Default GatewayYou can use the IPv6 Default Gateway screen to view o

Page 34

SFE2010/SFE2010P Administration Guide 1Welcome Introduction1IntroductionWelcome Thank you for choosing a Linksys Switch. This Switch will allow you to

Page 35

SFE2010/SFE2010P Administration Guide 37System ConfigurationUsing the ConsoleHTTP ConfigurationYou can use the HTTP screen to view and edit the HTTP s

Page 36

SFE2010/SFE2010P Administration Guide 38System ConfigurationUsing the ConsoleTo open the screen:1. From the Switch Main Menu, select 1. System Configu

Page 37

SFE2010/SFE2010P Administration Guide 39System ConfigurationUsing the ConsolePing IPv4You can use the Ping IPv4 screen to ping an IPv4 address.To open

Page 38

SFE2010/SFE2010P Administration Guide 40System ConfigurationUsing the ConsolePing IPv6You can use the Ping IPv6 screen to ping an IPv6 address.To open

Page 39

SFE2010/SFE2010P Administration Guide 41System ConfigurationUsing the ConsoleTraceRoute IPv4You can use the TraceRoute IPv4 screen to run a trace rout

Page 40

SFE2010/SFE2010P Administration Guide 42System ConfigurationUsing the ConsoleTraceRoute IPv6You can use the TraceRoute IPv6 screen to run a trace rout

Page 41

SFE2010/SFE2010P Administration Guide 43System ConfigurationUsing the ConsoleFile ManagementThe File Management Menu provides access to screens where

Page 42

SFE2010/SFE2010P Administration Guide 44System ConfigurationUsing the ConsoleTo enter the IPv4 Upgrade/Backup file name and location:1. Select Edit, a

Page 43

SFE2010/SFE2010P Administration Guide 45System ConfigurationUsing the ConsoleTo download a file from the specified location:3. Verify that the file na

Page 44

SFE2010/SFE2010P Administration Guide 46System ConfigurationUsing the ConsoleRestore System Default SettingsYou can restore the switch to the system d

Page 45

SFE2010/SFE2010P Administration Guide 2Getting to Know the SFE2010/SFE2010P2Getting to Know the SFE2010/SFE2010PThis chapter describes the ports, LEDs

Page 46

SFE2010/SFE2010P Administration Guide 47Port StatusUsing the ConsoleStack ConfigurationYou can use the Stack Configuration screen to specify the Stack

Page 47

SFE2010/SFE2010P Administration Guide 48Port StatusUsing the ConsolePort StatusYou can use the Port Status screen to view the port connection status.

Page 48

SFE2010/SFE2010P Administration Guide 49Port ConfigurationUsing the ConsolePort ConfigurationThe Port Configuration Menu provides access to screens wh

Page 49

SFE2010/SFE2010P Administration Guide 50Port ConfigurationUsing the ConsoleTo configure the ports:1. Select Edit. 2. Proceed as needed:a. Press the do

Page 50 - Port Status

SFE2010/SFE2010P Administration Guide 51System Mode (Layer 2 / Layer 3) SelectionUsing the ConsoleTo configure the PoE settings:1. Select Edit. 2. Pro

Page 51

SFE2010/SFE2010P Administration Guide 52HelpUsing the ConsoleTo edit the system mode or stacking mode:1. Select Edit. 2. Proceed as needed:a. Press th

Page 52 - Port Configuration

SFE2010/SFE2010P Administration Guide 53LogoutUsing the ConsoleLogoutThe Logout command lets you logout from the Ethernet switch.NOTE: When you issue

Page 53

SFE2010/SFE2010P Administration Guide 54US/Canada ContactsAContactsFor additional information or troubleshooting help, refer to the User Guide on the

Page 54

SFE2010/SFE2010P Administration Guide 55BCustomer Site SurveyUse this Customer Site Survey to gather customer contact information and other informatio

Page 55

SFE2010/SFE2010P Administration Guide 56How many users are at your site?Phone number and location of the telephone nearest to the Linksys equipmentAcc

Page 56

SFE2010/SFE2010P Administration Guide 3Getting to Know the SFE2010/SFE2010P1-48 The Switch is equipped with 48 auto-sensing, Ethernet (802.3) network

Page 57 - Contacts

SFE2010/SFE2010P Administration Guide 57Limited WarrantyCWarranty InformationLimited Warranty Linksys warrants this Linksys hardware product against d

Page 58 - Customer Site Survey

SFE2010/SFE2010P Administration Guide 58Obtaining Warranty ServiceTO THE EXTENT NOT PROHIBITED BY LAW, IN NO EVENT WILL LINKSYS BE LIABLE FOR ANY LOST

Page 59 -  Yes  No

SFE2010/SFE2010P Administration Guide 59DFederal Communication Commission Interference StatementThis Equipment has been tested and found to comply wit

Page 60 - Warranty Information

SFE2010/SFE2010P Administration Guide 60ESpecificationsModel• SFE2010 48-port 10/100 Ethernet Switch• SFE2010P 48-port 10/ 100 Ethernet Switch with Po

Page 61 - Technical Support

SFE2010/SFE2010P Administration Guide 61Environment Operating Temp: Operating Temp. 0ºC to 40ºC (32ºF to 104ºF)Storage Temp: Storage Temp. -20ºC to 70

Page 62 - Statement

SFE2010/SFE2010P Administration Guide 62Access Control ACLs - Drop or Rate Limit based on:Source and Destination MAC-basedSource and Destination IP ad

Page 63 - Specifications

SFE2010/SFE2010P Administration Guide 63Safety UL 60950-1IEC60950-1 CB / TUV/RhCSA-C22.2 No. 60950EN 60950AS/NZS 60950-1C-TickEMC FCC Part 15 (CFR 47)

Page 64

080312A-LB

Page 65

SFE2010/SFE2010P Administration Guide 4Getting to Know the SFE2010/SFE2010PSFE2010/P Back Panel Feature DescriptionPower The Power port is where you w

Page 66

SFE2010/SFE2010P Administration Guide 5Sample Network ConfigurationConnecting Devices 3Connecting Devices This chapter explains how to physically conn

Page 67 - 080312A-LB

SFE2010/SFE2010P Administration Guide 6Before You Install the Switch... Connecting Devices Before You Install the Switch... When you choose a location

Modèles reliés SFE2010P

Commentaires sur ces manuels

Pas de commentaire